It is possible to measure the in-die tablet height correctly with the four additional transducers. If the height measurement is not corrected for punch deformation, an error of about 150 µm at 50 kN occurs. By correcting data for the machine deformation the height can be measured with the two premounted transducers but a higher measurement error has to be accepted.